top of page

CHEMISTRY ANALYZER

FULLY-AUTOMATED

TECHNICAL SPECIFICATIONS

SAMPLE/REAGENT POSITION    
- 40pcs sample position

- Reagent refrigerated function

- 40pcs reagent position  

REACTION CUVETTES
- 60pcs reusable plastic cuvettes

- Automatic blank testing for cuvette

- Colorimetry system in the pattern of light splitting behind cuvette

- Dismountable, easily replacement

SAMPLE/REAGENT/MIXING PROBE
- Automatic liquid level detect

- Collision protection function

- Probe internal/external washing

- Independent mixing probe

7-STEP AUTO CLEANING SYSTEM
- Automatic 7-step washing

- Hi-tech washing station to ensure accurate results

- With low water consumption: 1-2L/H

SYSTEM FUNCTIONS

- Analysis Methods: end-point, kinetic, two-point, double-reagent, double-wavelength, multi-standard etc, open to various reagents

SAMPLE/REAGENTS HANDLING

- Sample volume: 1.6-50uL, 0.1uL step

- Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100

- Reagent Position: 40pcs

- Reagent Volume: 10-500uL, 0.5uL step

TC200

FULLY AUTOMATED CHEMISTRY ANALYZER

chemistry analyzer
TECHNICAL SPECIFICATIONS

OVERALL PERFORMANCE        
Equipment Type              
Analysis Rate                   
Test Principle                   
Analysis Method       

                      

 


SAMPLE SYSTEM            
Sample Tray                     
Sample Volume              
Sample Probe     

           
Sample Containers     

 

REAGENT SYSTEM
Reagent Tray                   
Reagent Volume           
Reagent Probe

               
Reagent Refrigeration  

     
Fully automatic discrete, STAT priority.           
Constant speed 300T/H. (without ISE)                
Colorimetry, turbidimetry.                
End-point 2 kinetics, fixed-time etc

single/double wavelength, linear and non-linear calibration.    

                 
       
49 Sample positions, random access of all samples    
2-50ul, 0.1ul increment.

Liquid level detection, the remaining detection, collision protection etc.          

Sample cups, Micro tube. Original blood-collection tube, etc.

 

 
56 reagent positions            
R1:25-300ul, R2:10-15ul, 0.1ul increment
Liquid level detection, the remaining detection, collision protection etc.        

4-15°C, independent power supply, 24-hour non-stop refrigeration.

NT 300

FULLY AUTOMATED CHEMISTRY ANALYZER

chemistry analyzer
TECHNICAL SPECIFICATIONS

FEATURES        
- Fully automatically, discrete, random STAT function

- Online test items: at most 40 testing items

- Throughput: 260 tests/hour

- Analysis Method: end-point, kinetic, two-point, double

- Reagents, double-wavelength, multi-standard etc, open to various reagents

- Data Processing: memory up to 200,000 patient's data    

SAMPLE/REAGENTS HANDLING  
-Sample Position: 40pcs (Include standard, QC, STAT positions)

- Sample volume: 2-50uL, 0.1 uL step

- Sample Probe Cleaning: automatic internal & external washing

- Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100

- Reagent Position: 40pcs (with refirgerated function, 2°C-8°C)

- Reagent Probe: automatic liquid detect, with collision protection function

- Reagent Probe Cleaning: automatic internal & external washing

 REACTION SYSTEM
- Reaction Cuvette: 90ocs made of reusable plastic

- Opical Length of Cuvette: 6mm

- Reaction Volume: 200-500uL

- Reaction Time: 8-10 minutes

- Reaction Temperature: 37°c-0.1°c

- Mixing System: Independent mixing stirrer

OPTICAL SYSTEM    
- Light Source: halogen-tungsten lamp

QC

- Various QC managements, insert QC randomly; save, display & print QC chart; define different QC in advance

TC6030

FULLY AUTOMATED CHEMISTRY ANALYZER

chemistry analyzer
TECHNICAL SPECIFICATIONS

FEATURES        
- Fully automatically, discrete, random STAT function

- Online test items: at most 80 testing items

- Throughput: 400 tests/hour

- Analysis Method: end-point, kinetic, two-point, double

- Reagents, double-wavelength, multi-standard etc, open to various reagents

- Data Processing: memory up to 2 million patient's data    

SAMPLE/REAGENTS HANDLING  
-Sample Position: 93pcs (Include standard, QC, STAT positions)

- Sample volume: 2-50uL, 0.1 uL step

- Sample Probe Cleaning: automatic internal & external washing

- Sample Dilution: automatic/Manual pre-dilution, with dilution ratio up to 1:100

- Reagent Position: 40pcs (with refrigerated function, 2°C-8°C)

- Reagent Probe: automatic liquid detect, with collision protection function

- Reagent Probe Cleaning: automatic internal & external washing

 REACTION SYSTEM
- Reaction Cuvette: 90pcs made of reusable plastic

- Optical Length of Cuvette: 6mm

- Reaction Volume: 200-500uL

- Reaction Time: 8-14 minutes

- Reaction Temperature: 37°c-0.1°c

- Mixing System: two Independent mixing stirrer

OPTICAL SYSTEM    
- Light Source: halogen-tungsten lamp

- Wavelength: 340-750nm, 12 wavelengths, precision 2nm

- Spectrophotometry: rear spectroophotometry

- Test Range: 0-4.0 Abs

- Resolution: 0.001Abs

TC6090

FULLY AUTOMATED CHEMISTRY ANALYZER

chemistry analyzer
Semi-automated

SEMI-AUTOMATED

TECHNICAL SPECIFICATIONS
chemistry analyzer

Test mode: Kinetic, End point, Two point, Absorbance

Wavelength: 7 standard filters, 340,405,492,510,546,578,630nm, 1 free position

Wavelength precision: ±2nm, width ≤ 10nm

Absorbance range: 0~4.500 Abs

Absorbance precision: outside 0.0001 Abs, inside 0.00001 Abs

Carryover: <1%

Repeatability CV: <1%

Incubator: 37°C, 30°C, 25°C, and others, Precision: ±0.1°C

Sample Volume: 0~3000ul (500ul recommend)

Data Storage: 10000

Quality control curve: X SD CV% L-J quality control curve for each test item

Flow cell: 32 ul quartz glass, 10mm

Lamp: Philips 6V 10W halogen lamp with longer life time

Screen: 7 inch color LCD

CPU: ARM series high speed micro CPU

Printer: Internal thermal sensitive printer

Interface: RS-232

Work Environment: Temperature 0°C~40°C, Humidity: 80%

Power supply: 100~240VAC, 50~60Hz, 100VA

Dimension: L340mm*W270mm*H160mm

Weight: 5kg

Liver Function: ALT AST ALP T-BIL TP ALB TTT CHE NH3

Renal Fucntion: BUN CRE UA URE CO2-CP Y-GT

Lipids: T-CHO TG HDL-C LDL-C

Cardiac function: CK CK-MB LDH

Immun proteins: IGA IGG IGM C3

Others: GLU HGB AMS

iCHEM 535

SEMI-AUTOMATED CHEMISTRY ANALYZER

TECHNICAL SPECIFICATIONS

Instrument: Fully-Auto Glycated Hemoglobin HbA1c Analyzer

Model: JL 760

Test Method: Low pressure ion exchange liquid chromatography (LPLC)

Test Item: HbA1ab HbA1c

Sample Type: Whole blood, hemolysis blood

Sample Volume: Whole blood 20ul, hemolysis blood 800ul

Photometer: 415nm LED Integral flow colorimeter

Analysis Time: 3.5mins

Precision: CV ≤ 3.0%

Display: 320*240 LC Graphic display, displaying real-time testing curve

Printer: 58nm Thermal printer, printing test curve and report

Panel: 0-9, YES, NO, START, STOP, ST, PRINT

Data Storage: 2G TF Card, more then 100,000 test reports storage (including Curve)

USB Port: Support remote upgrading, LIS Interface

PS-2 Port: External Barcode Scanner

Power Supply: 220V ± 22V, 50Hz ± 1Hz

Working Environment: Temperature 10°C~30°C, Relative humidity 30%~75%

Size: 550mm*405mm*347mm

Weight: 15kg

JL 760 (LPLC)

GLYCOSYLATED
HEMOGLOBIN

hba1c
Glycosylated Hemoglobin

GLYCOSYLATED HEMOGLOBIN

TECHNICAL SPECIFICATIONS

Instrument: Fully-Auto Glycated Hemoglobin HbA1c Analyzer

Method: High pressure ion exchange liquid chromatography (HPLC)

Sampling System: Automatic identification system for Primary Tube & sample cup

                                   Primary tube with cap puncture automatically

Throughput: <3mins per sample

Sample Tray: 15 samples position CAL (QC1) & CAL2 (QC2) position, ST

Sample Type: Venous Blood, Finger Peripheral Blood or hemolyse blood

Sample Volume: 5uL whole blood, or lyse blood (ratio 5uL:1000uL)

Test Range: HbA1c: 3-18%; 14-191mmol/mol, HbF:0.3-5%

Test Item: HbA1c HbF & B-Thalassemia

Heat system: Temperature range for column 5-40°c, can keep the constant 

                          temperature, the fluctuation +-0.2°c

Light system: 415nm LED light, long life span, the fluctuation is 2mv per hour

Printer: 57mm Thermal printer, printing test curve and report

USB Port: Support  LIS system, software upgrade online, external barcode scanner

                   optional

Barcode: External Barcode Scanner optional

Display: 8 inch LCD colorful touch screen, 162mm*122mm display real-time testing

                curve

Data Storage: more than 10,000 test reports storage (including Curve), Inquiry freely

Language: English, Spanish, Russian, Portugese, Japanese

Report: NGSP, IFCC result

               HbA1a, HbA1b, HbF, HbA1c, HbA0, variant sample report.

               Optional PC software for regular report format

Work Condition: Temperature 5°C~40°C, Relative humidity 30%~75%

Dimension: 460mm*445mm*390mm

Weight: 28kgs

NH-20 (HPLC)

GLYCOSYLATED
HEMOGLOBIN

hba1c